Equipment / Facility & heating
Authorized dealerWaste oil heaters.Turn used oil into heat.
EnergyLogic furnaces and boilers turn the used oil your shop already generates into heat for the bays. Total Tool installs them, cleans and tunes them every season, and services Clean Burn units too.
Cleanings book up before heating season. Get on the schedule early.
Three questions
Size your heater
Square footage picks the model, and your used oil decides how far it carries you. The site visit confirms both before anything is ordered.
Floor area to heat
How you want the heat delivered
Used oil you generate per month
Starting point
Estimates only. Insulation, ceiling height and door traffic change the real heat load, so we confirm it on site.
Answer all three
Your heater shows here
Pick your floor area, how you want the heat, and roughly how much used oil you collect.
Browse the range
Featured heaters and boilers
Pick a model to add it to your request, or ask about models not shown here.
Warm-air furnaces
Ceiling-hung or tank-mountedUL-listed furnaces with an integrated air compressor and stainless steel heat exchanger, so they run without tying into shop air.

Big heat for small spaces: a vertical, floor-mounted furnace with its own 10-gallon tank, for up to 1,750 square feet at about half a gallon per hour.
75,000 BTU/hr · New
Heats up to 3,500 square feet, roughly one to four service bays. 1.0 gallon per hour at full fire.
140,000 BTU/hr
Heats up to 5,000 square feet, roughly four to eight service bays. 1.4 gallons per hour at full fire.
200,000 BTU/hr
Heats up to 9,000 square feet, roughly eight or more service bays. 2.5 gallons per hour at full fire.
350,000 BTU/hrHydronic boilers
Hot water and radiant floorASME-certified carbon steel vessels built for waste oil from the ground up, for radiant floors, hydronic loops, snow melt and, with the optional coil, domestic hot water.

1.4 gallons per hour, 30-gallon capacity and 230°F water output for radiant floors and hot water loops.
200,000 BTU/hr
2.7 gallons per hour and 43-gallon capacity for larger radiant and hydronic systems.
375,000 BTU/hr
3.6 gallons per hour and 52-gallon capacity, rated just under the EPA's 0.5 million BTU on-site limit.
499,000 BTU/hrWaste oil tanks
Cleaner fuel inUsed oil carries sludge and water, so EnergyLogic builds tanks specifically for it.
Ways to set it up
Built around your building
EnergyLogic's layouts cover most shops. We plan the version that fits yours at the site visit.







The technology
Engineered for used oil
Used oil is inconsistent: different weights, water in the tank, sludge on the bottom. EnergyLogic's patents are aimed squarely at that problem.
No manual adjustments
A patented side-suction metering pump delivers consistent fuel regardless of fuel type, and the patented Accutemp® preheater handles the widest range of viscosities.
Oil in, water and sludge out
The elevated pickup draws above the water and sludge layer, through a spin-on stainless mesh filter, so only used oil reaches the burner.
No shop air required
The on-board compressor means the heater runs around the clock without depending on your shop air system.
Built to last decades, not years
Designed to prevent corrosion, warping and weld breakage, with an open design and swing-away burner that make cleaning straightforward.
See it in action
A closer look at EnergyLogic waste oil heating, from EnergyLogic.
The rules
Burning used oil, by the book
Federal EPA rules let a shop burn its used oil for heat without being treated as an off-specification used oil burner, as long as three conditions are met.
Every EnergyLogic furnace and boiler is rated at or under that limit, and the largest boiler tops out at 499,000 BTU per hour. Source: 40 CFR 279.23. State and local rules can add requirements.
Side by side
Furnace or boiler
Both burn the same used oil. The difference is how the heat reaches the floor.
| Warm-air furnace | Hydronic boiler | |
|---|---|---|
| Heat delivery | Warm air blown from overhead | Hot water to radiant floors or a hydronic loop |
| Range | 75,000 to 350,000 BTU/hr | 200,000 to 499,000 BTU/hr |
| Mounting | Ceiling-hung or tank-mounted (12 ft minimum ceiling tank-mounted) | Floor-standing, tied into the water system |
| Good to know | Integrated compressor, no shop air needed | Low pressure (30 psi max); return water must stay above 140°F |
| Best fit | Open service bays | Radiant floors and existing hot water systems |
The vendor
Why Total Tool backs EnergyLogic

Patented where it matters
EnergyLogic has been on the leading edge of waste oil combustion from the start, and its patents sit exactly where used-oil heaters usually fail: fuel delivery, preheating and the heat exchanger. The result is a heater that handles a wide range of used oils without manual adjustment.
Total Tool sells, installs and services them, and the same crews do the annual cleaning and combustion tune-up that keeps the warranty and the burner happy.
Why buy it here
Installed, cleaned and tuned every season
Total Tool has equipped shops across upstate New York, Vermont, western Massachusetts and Connecticut since 1983. A waste oil heater runs best with a yearly cleaning, and our service crews do it before the cold arrives.
- Sizing, placement and ceiling height checked before anything ships
- Flue, fuel tank and pump installed by our own crews
- Annual cleaning and combustion tune-up before heating season
- Burner service and replacement parts
- Financing, and quotes formatted for purchase orders
We service both


Common questions
Before you buy a heater
Is it legal to burn used oil in a shop heater?
Under federal EPA rules, yes, when the heater burns only oil you generate or oil from household do-it-yourselfers, is designed for no more than 0.5 million BTU per hour, and vents outside. State and local rules can add requirements.
What can an EnergyLogic heater burn?
Crankcase oils, ATF, hydraulic fluid, #2 fuel oil and diesel, from 5 to 90 weight, including synthetics.
Can I burn used oil from other businesses?
Not under the federal on-site space heater rule. It covers oil you generate yourself and oil from household do-it-yourselfers only.
How often does it need service?
Once a year. We clean the heat exchanger and burner and do a combustion tune-up before heating season, which is the best time to book.
Do you service Clean Burn heaters?
Yes. We clean, tune and repair Clean Burn and EnergyLogic heaters and boilers, whoever installed them.
How high does the ceiling need to be?
A tank-mounted EnergyLogic furnace needs at least a 12-foot ceiling. We check clearances and the flue route at the site visit.
Request a quote or cleaning
Tell us about the building
Square footage, ceiling height and roughly how much used oil you collect. For a cleaning, just the make and model.
On your request
Interested in financing? Ask for payment options → · How financing works
No heat? Call. It is faster than the form.